NetShelter SX, 42U, w/o Doors, Black
NetShelter SX 42U 750mm Wide x 1070mm Deep Enclosure Without Sides Without Doors Black More Info
208V, 50/60Hz, 35A, 12.5kVA, 0U, 56 x 89 x 1778mm, 8.08kg, Black
Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Power DelaysAllows users to configure the sequence in which power is turned on or off... More Info
Rack PDU Blue label kit (Quantity 10 units)
Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also... More Info
NetShelter SX 48U 600mm x 1200mm, w/doors, no sides, black
NetShelter SX 48U 600mm Wide x 1200mm Deep EnclosureFeature-rich IT enclosures optimized for row-based InfraStruxure architecture, cable management, power distribution, and maximizing airflow.Includes: Baying hardware, Documentation CD, Key(s), Leveling feet, Mounting Hardware, Pre-installed casters, Side Panels, User ManualGuaranteed Compatability Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19" equipment. The APC "Fits Like a Glove" money back guarantee provides peace of mind that all of your... More Info
Rack Air Removal Unit SX 100-240V 50/60HZ for NetShelter 600mm enclosures
High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, returns the warm air to the plenum and eliminates hot spots from the data center. Through automatic fan speed control based upon temperature, the fans will self-adjust for optimal performance. With a unit-mounted LCD display, users can view temperatures at the rack, monitor alarm conditions and... More Info
Rack PDU Red label kit (Quantity 10 units)
Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also... More Info
NetShelter SX, 48U, w/o Doors, Black
NetShelter SX 48U 750mm Wide x 1200mm Deep Enclosure Without Doors Black More Info
Rack PDU 2G, Switched Plus, ZeroU, 30A, 200/208V, (21) C13 & (3) C19
Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up... More Info
NetShelter SX, 48U, w/o Doors, Black
NetShelter SX 48U 750mm Wide x 1200mm Deep Enclosure Without Sides Without Doors Black More Info
600x35x1915mm, 10kg, White
NetShelter SX 42U 600mm Wide Perforated Curved Door White- Rack system components that can be added to existing racks if requirements change. - Includes : Door handle , Door mounting hardware , Installation guide , Key(s) - Door ventilation exceeds 830 in2 (5355 cm2) Adequate ventilation is required for proper operation of today's servers. NetShelter Enclosures include fully perforated front and rear doors to provide ample ventilation for servers and networking equipment. The perforation pattern provides 844 square inches of open area on... More Info
Rack PDU 2G, Metered, ZeroU, 17.2kW, 208V, (6) C13 & (12) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
75 x 225.8cm, IP20, 19", 48U, 1020.58KG
NetShelter SX 48U 750mm Wide x 1200mm Deep Networking Enclosure with Sides White Feature-rich rack enclosure optimized for easy installation, managing cables, integrating power distribution, and maximizing airflow. Includes: Baying hardware, Key(s), Keyed-alike doors and side panels, Leveling feet, Mounting hardware, Pre-installed casters, Side panels, Vertical cable managersCable protection and pass-through Smooth plastic fingers provide proper bend radius.High density cable management The vertical mounting rails are opened up for... More Info
NetShelter SX Colocation 20U 600mm Wide Perforated Curved Door Black
Rack components that can be added to existing racks if requirements change.Includes: Door handle, Door mounting hardware, Installation guide, Key(s) More Info
Rack PDU 9000 Switched, ZeroU, 30A, 200/208V, (21) C13/C15 & (3) C19/C21
Field-replaceable NMCIntegrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.High Retention OutletsWith no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.60C Operating TemperatureSelect 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in... More Info
48U 800 x 1200mm
Integrated joining hardware with multiple width enclosure alignment Enclosures include pre-installed joining hardware to join enclosures in a row and provide additional stability to the enclosure. The pre-installed joining hardware includes holes for joining to an adjacent enclosure at 600mm centers or 24in centers depending upon the floor layout.Enclosure assemble-to-order (ATO) options capable The Enclosure ATO (Assemble-to-Order) options provide a level of customization for enclosure customers beyond the standard enclosure models. This... More Info